Désolé, cet article est seulement disponible en Anglais Américain et Allemand. Pour le confort de l’utilisateur, le contenu est affiché ci-dessous dans la langue par défaut du site. Vous pouvez cliquer l’un des liens pour changer la langue du site en une autre langue disponible.

Lausanne, CHE

Waste to Energy

Throughput

160'000 t/a

Energy recovered

electricity, district heat

Thermal energy

2 x 40 MWth

With a high level of efficiency, low emissions and virtually no cloud of steam, the thermal waste treatment plant run by the cantonal special-purpose association TRIDEL meets all the requirements of a facility located near an urban recreation area. Lausanne’s plant with state-of-the-art technology replaced what had once been the oldest plant of its kind in the world still in operation.

Facts

  • Type of system: water-cooled HZI reciprocating grate
  • Fuel: municipal waste, hospital waste
  • Calorific value: 14.4 MJ/kg
  • Number of lines: two
  • Boiler design: four-pass boiler with external economiser
  • Flue gas treatment: electrostatic precipitator, wet scrubber, SCR system, wastewater treatment

Client

  • TRIDEL SA

Commencement of operation

  • 2006

Components supplied by HZI

  • combustion, flue gas treatment, residue handling